Features of a cold attic floor on wooden beams


Of all types of attic and interfloor ceilings, 2/3 of private developers prefer to install the ceiling on wooden beams.
The popularity of such work is due to its speed and low cost. Having skills in this area, you can install such a ceiling without involving a construction crew, which will significantly save your budget.

This article will tell you how to calculate the necessary materials and carry out the installation of an attic floor from A to Z.

Description

The installation of a cold attic is the simplest solution from a technological point of view, especially when compared with the alternative warm option or the construction of an attic. The air temperature of such a room, as a rule, is slightly higher (no more than 4 degrees) than the air temperature outside.

The composition of the structure under consideration includes the following elements (from top to bottom):

  • roofing;
  • external attic walls;
  • insulated ceiling between the attic and the living space underneath.

It should be noted that insulation of the ceiling of a cold attic with mineral wool or other heat-insulating material can be done both from above and below from the side of the living room, regardless of whether it is wooden or concrete.

The option under consideration has a number of advantages:

  • reliability of waterproofing of the coating. It is achieved by reducing the number of superstructures protruding above the roof, which, as a rule, are its weakest points;
  • ease of operation. The existing internal under-roof space makes it easy to inspect and maintain all floor and roof structures;
  • the overlap area is smaller than the area of ​​the pitched roof, which reduces the area of ​​possible heat loss;
  • availability of additional operational premises.

In order for the benefits of a cold attic design to be fully realized, it is necessary to correctly and competently resolve several issues related to the insulation of the attic floor, as well as proper ventilation of the cold attic.

Lighting

In order for natural light to freely enter the rooms under the roof, translucent structures are needed. In this case, the only correct solution would be to install skylights. An important point in the process of preparing to install a window into the roof slopes is the manufacture of a strong wooden frame on the inside, which will help hold the window frames and prevent possible deformation. The frame is installed between the rafter legs, so the width is ordered taking into account this distance and the thickness of the beams. Windows can be installed on gables or directly in the roof of the house. What are the advantages of roof windows?

  1. Saving on energy costs. Such windows allow you to increase the transmission of natural light by 40%.
  2. Exquisite design. Windows help create a unique atmosphere in the room under the roof; they organically complement the design, creating spaciousness in the room.
  3. Functionality. Manufacturers offer various configurations and functional loads of windows for attic spaces.

Dormer windows are an excellent source of daylight

As for wiring into the attic to create high-quality artificial lighting, there are several proven methods:

  • laying wires over the walls, hiding them in special plastic boxes;
  • arrangement of hidden electrical wiring by laying the wires under the inner lining.

The first method is the simplest; you can do it quickly and easily with your own hands. The second method is more technically complex, since the fire safety standards and requirements for a private home must be taken into account. Hidden electrical wiring is installed during the installation of the frame, wall and ceiling cladding.

When the electrical wiring is installed in the attic, all sockets and switches are placed in their places, you can begin the most exciting stage - interior planning. Flights of imagination are welcome here! You can choose classic style solutions, cozy Country or gentle Provence. For young people you can create an urban room under a roof in the Loft style, and for children - a fabulous dream island.

The easiest way to highlight the beauty of your attic interior is through thoughtful lighting.

Transforming a dusty and dark attic into a cozy and spacious room under the roof itself is a labor-intensive process and requires financial costs. Knowing the secrets and tricks, following the rules and advice of experts, you can quickly transform an uninhabited cold attic under the roof into additional living space.

Transforming an Abandoned Attic

Organization of ventilation

The main purpose of ventilation in this case is as follows:

  • removal of excess water vapor penetrating through the ceiling from below from the residential part of the building, in order to prevent the appearance of condensation and moistening of the insulation and roof truss system;
  • creating an optimal microclimate.
  • Ventilation occurs through two types of vents:
  • cornices (the air passing through them is called supply air);
  • ridge (exhaust air passes through them).

Their total area should be 0.2-0.33% of the roof covering area, in other words for a covering area of ​​1000 sq.m. The area of ​​the vents should vary from 2 to 3.33 sq.m. This calculation is carried out in accordance with SNiP standards, and it is quite simple to do. It applies equally to various options for roofing pie covered with metal tiles, corrugated sheets or soft tiles.

The basic rule for the location of vents is as follows: the ventilation system operates most efficiently when the inlet and outlet openings are as far apart as possible.

In most cases, a scheme is used with an approximately uniform arrangement of vents around the perimeter of the building under the overhangs and along the entire length of the roof ridge.

Additional ventilation is often performed through dormer windows installed on the gables or roof slopes, which help with enhanced ventilation. When installing them, they are guided by the rule of symmetry: in order to prevent the presence of unventilated areas, dormer windows should be located on opposite slopes.

Typically, dormer windows are made of three types:

They are installed in such a way that the lower part of the window is no more than 1 meter from the floor level, and the upper part is at least 1.75 meters higher from the floor level. Often, dormer windows are used as an exit to the roof for the purpose of inspecting the roof and the elements of the ventilation system and chimneys installed on it. Sometimes a special hatch is installed for this purpose.

In order to prevent birds from entering, the vents are equipped with protective nets or gratings, and blinds are installed on the dormer windows.

Is it possible to use roofing felt?

Sometimes roofing felt and its analogues are used as waterproofing for pitched roofs. But these materials are intended for waterproofing flat roofs over a continuous floor.

The technological map of the TechnoNikol company for the installation of bitumen roll materials indicates that the roofing material is attached to the base using mastics or by fusing.

Mechanical fasteners at large roof slope angles are used as additional “point” fixation to prevent bitumen waterproofing from slipping in hot weather. And this limits the scope of use of roofing felt on pitched roofs.

On those roofs where the slope angles are large and the technology for laying the roof is continuous, lathing is not needed, it is not economically profitable to install it, even though roofing felt is cheaper than waterproofing films. But only mechanical fastening along a row sheathing does not provide sufficient reliability of fixation due to the low tensile strength of roofing material.

Thermal insulation from the attic

This option is considered the most effective. A wide variety of ceiling insulation for a cold attic can be used: mineral wool (the most commonly used option), polystyrene foam, expanded clay, etc.

Sequence of work stages:

  • vapor barrier device (ordinary PVC film or modern materials with much higher performance characteristics can act as a vapor barrier material);
  • laying mineral wool thermal insulation in two layers;
  • creation of a protective coating from cement bonded particle boards.

This unit is one of many possible ones that fulfill the basic requirements for insulating the ceiling of a cold attic and allow you to obtain the following advantages:

  • due to the presence of a vapor barrier, moisture does not enter the insulation;
  • the DSP coating allows you to move freely without damaging the insulation;
  • the design is quite reliable and durable (to further increase the service life, it is recommended to treat the surface of the DSP with antiseptics, which significantly reduce the likelihood of fungi or mold appearing).

It is imperative to additionally insulate the perimeter of the attic. It is carried out by laying a layer of mineral wool 0.75-1 meter wide and a layer thickness of 10 cm. This will reduce or completely avoid the risk of freezing in the upper floor rooms in the corners.

Sawdust

Sawdust is a product of lumber processing in the woodworking industry. This is the cheapest insulation for attic floors, since you can buy sawdust at any sawmill for free. Thus, sawdust is still an option as a reliable heat insulator in attic spaces.

On a note! Sawdust is of organic origin, therefore, it is completely harmless to human health. Since ancient times in Rus', sawdust mixed with clay has been used as insulation in attics.

Sawdust has the following advantages:

  1. Low cost of thermal insulation. Probably, the popularity of such insulation lies precisely because of this factor: its cost is almost equal to the cost of transportation.
  2. Safety for human health. Wood shavings and sawdust do not cause skin irritation, allergies, or poisoning, which cannot be said with complete confidence about modern insulation materials.
  3. Low thermal conductivity coefficient. Unlike wood, chips have a porous structure, so they have low heat conductivity.
  4. Easy installation. To form a heat-insulating layer in the attic floors, no special skills are required. You just need to mix sawdust with clay or lime, and then pour it into the space between the attic floors.

The only significant drawback is the fire hazard of the material, despite the mixture with other non-flammable substances.


Thermal insulation from sawdust

Thermal insulation from inside the living room

Installing a ceiling in a private house with a cold attic and insulation from the inside is done much less frequently, since the work is accompanied by a number of disadvantages:

  • the ceiling level decreases;
  • Carrying out thermal insulation work disrupts the finishing, if it has already been completed, and requires subsequent repairs;
  • not all thermal insulation materials are useful and environmentally friendly, which leads either to an increase in the cost of work or to a decrease in living comfort. For this reason, the use of mineral wool is not recommended. In addition, it is always recommended to leave a ventilation gap between the thermal insulation material and the finishing material.

Attic design with ceiling

Construction of an attic, which, of course, expands the living space, is much more expensive and requires certain knowledge, time and labor costs. The installation of a cold attic floor is many times cheaper and simpler.

The installation of an attic floor on wooden beams is a layer cake:

  • plank board or roll;
  • vapor barrier;
  • ventilation gap;
  • insulation;
  • ventilation gap;
  • vapor barrier;
  • floor.

Ventilation is carried out through gables or roof slopes. They also make dormer windows, placing them on opposite slopes so that air penetrates into all corners of the room.

Dormer windows are a difficult element to install, but useful. They can have different shapes: triangular, oval, they are located at a height of 1 meter from the floor, equipped with grilles and blinds. Through them it is convenient to go onto the roof for inspection, maintenance, checking the chimney, antenna and other things.

Beams for the attic

The attic floor is made using wooden beams after the installation of load-bearing elements is completed. This is the simplest and best way to properly arrange the technical area.

The attic floor structure is usually made of wooden beams. These load-bearing elements have a number of advantages:

  • maximum coverage 4.5 m between supports;
  • light weight, load on the building, savings on the foundation;
  • ease of installation, without the use of lifting equipment or a crane;
  • availability of wood as an inexpensive material;
  • speed of work, the ability to install an attic floor in a day or two;
  • possibility of using any soundproofing materials.

To make beams, coniferous wood is used that is resistant to moisture, rot, and fungus. The cross-section of the beams for the attic floor must correspond to the load; climatic conditions and the thickness of the heat-insulating material should be taken into account. Beam dimensions of 150x200 mm are used if a serious load is expected on the attic floor. For example, it is planned to install a water tank and a transformer. For minimal load, beams of 100x150 mm are used.

The desire to save money and install 50x100 mm beams is not approved. An extremely important element of the house is the attic floor, which provides thermal insulation, sound insulation and reliability of the ceiling. The quality of the overlap guarantees savings in heat and heating costs.

You can calculate the number of wooden beams for the attic floor as follows. Divide the length of the room by 60-100cm (the distance between the beams), add 2 pieces to the resulting value, which will be laid on the walls. Beams should be laid on load-bearing and external walls.

What does it consist of?

At the heart of any interfloor ceiling, be it a basement or an attic, are large-caliber beams, on which a so-called pie of flooring, insulation and external finishing is placed. The difference between the structure of the attic and the basement is only in the cross-section of the beams . The attic requires stronger beams, especially if we are talking about a warm room where furniture will stand and people will walk around.

For cold floors, the standard is timber or other versions of beams with a section of 100x150. It is impractical and unsafe to use a smaller thickness. For a stronger floor, you can use 100x200 beams. They are heavier, but you will need less of them, since the step can be increased from the standard 60 cm to 1.5 m.

Next, a vapor barrier is laid on the side of the lower room, filling it with a rough ceiling, for example from OSB boards. On the attic side, insulation and waterproofing are laid and a rough attic floor is created .

In another option, you can use metal beams, for example, I-beams. They are more durable, but when used, the thermal conductivity of the entire cake suffers. Metal has high thermal conductivity, which increases the cost of insulation.

Another option for attic flooring is concrete slabs, which are laid ready-made on the load-bearing walls of the house. The advantage of a reinforced concrete floor is its high strength and the absence of the need to install a vapor barrier. The downside is that it is cold and heavy, as well as expensive and labor-intensive from an installation point of view.

Installation of wooden attic beams

The installation of an attic floor is carried out in several stages, each of which determines the quality and reliability of the structure. The work algorithm looks like this:

1. Preparation. The required length is cut, the wood is treated with a special compound that protects it from rotting, swelling and other troubles, the edges of the beam are wrapped with roofing felt, then the finished element is lifted up.

2. Laying in two ways:

  • without protrusion beyond the external walls;
  • with outlet beyond the outer walls.

It is necessary to lay it along the length at the required distance in relation to other structural elements; for any installation method, the following is taken into account:

  • the maximum span width should not exceed 4.5 meters;
  • the timber is laid on the ends of the walls; in some cases, a mauerlat is used - this is a thick beam secured with thick nails or steel studs into the walls around the perimeter;
  • roofing material is laid under each beam layer to ensure waterproofing;
  • the pitch of wooden beams is selected based on the size of the thermal insulation material.


3. The attic floor on wooden beams is carried out taking into account the construction of the ramp, which is a covering made of boards and slabs.
Waterproofing, vapor barrier, and insulation are laid between the upper and lower eaves. The lower flooring is made on supports to which boards are attached, but it is better to use slabs or sheets of plywood 15-20mm thick. Fastenings are carried out with self-tapping screws in increments of 10-15mm so that the heat-insulating materials are securely held. In order to mount the most durable structure, you need to fill the bottom of each beam with 50x50mm wooden blocks; they form a ledge on which boards or sheets are placed. You also need to secure the roll to the bars with self-tapping screws. The advantages of this design are exceptional reliability; the disadvantages will appear in the finishing of the ceilings, on which these bars will have to be sealed and hidden. Such a structure should be installed if you plan to actively use the attic.

Video on the topic:

4. The final stage of installing an attic floor on wooden beams is the installation of the floor, for which boards are sewn on top to act as a subfloor. For the finished floor, a tightly laid tongue and groove board is used.

Requirements

Regardless of the type of attic (cold, warm) and the beams used during installation (wooden, reinforced concrete, metal), general technical rules for the arrangement and use of basic and protective layers apply to them.

At the same time, the formation of vapor and waterproofing is subject to a number of regulatory technical requirements , which include provisions relating to the ceiling itself and materials for installation - these are:


  • GOST R 58796-2020;

  • SNiP II-26-76;
  • SNiP 23-01-99;
  • SP 31-105-2002;
  • SP 17.13330.2017;
  • SO-002-02495342-2005;
  • SP 17.13330.2011;
  • MDS 12-34.2007.

Characterizing the listed standards, we can highlight the following main points regarding the arrangement of vapor and waterproofing:

  1. The materials used must be produced in an industrial environment, be of the highest quality, have accompanying documents from trusted manufacturers, certificates and instructions.
  2. The consumables used must belong to the non-flammable group “NG”.
  3. Vapor barrier and waterproofing must be resistant to water and repel condensation well. They must be wrapped around all or part of the beams along the joists adjacent to the wall.
  4. All materials used must be securely attached to the prepared surface using glue and fasteners.
  5. During installation, you can use dense and liquid materials (for example, for waterproofing).
  6. Between the layers of the cake, it is imperative to create a ventilation layer (at least 25 mm), which is formed under the sheathing, before laying the insulation, which is applied after the waterproofing.
  7. The working material must adhere well to the surface and adhere to any substances.

In addition, vapor barrier and waterproofing products do not have to be expensive. They are also laid according to the spacing of steps between the beams (minimum 4 m), in accordance with the thickness specified in the work project.

Thanks to the technically correct creation of the cake, using steam and waterproofing, it is possible to create additional space, which is useful for various household purposes.

The importance of vapor barrier and methods of its installation

Vapor barrier of the attic floor ensures the safety of the wooden floor. It extends the life of the roof, helps create an optimal microclimate in residential premises, removing excess moisture, and prevents heat loss. You should choose the material for vapor barrier carefully, without any intention of saving money.

Vapor barrier material has different side structures. On one side, the rough surface absorbs moisture, the other side with a film prevents moisture from penetrating into the heat-insulating layer.

The vapor barrier is installed, as is already clear, between the ceiling and the insulation in the attic floors. Materials used:

Fabrics reinforced with a special mesh may have perforations. You can also use non-perforated film, leaving gaps during installation. The reinforced film has a metallized surface. The film is spread downwards with the metallized surface to reflect heat loss.

A layer consisting of fibers absorbs moisture, then evaporates it naturally. The materials are durable and resistant to ultraviolet rays.

There are also other vapor barrier materials that can be used when equipping the attic floor with wooden beams as a vapor barrier. These are varnishes and mastics, asphalt, bitumen, bitumen-kukersol. Today, such materials are rarely used, preferring non-woven fabrics of synthetic origin. These are so-called “breathable membranes”, capable of transmitting moisture and air, multi-layer, single-layer, equipped with aluminum foil.

The material is placed with a 20 cm overlap on the wall, secured with a stapler, the rough side down.

Video on the topic:

Vapor barrier membranes

Diffuse (breathable) membranes are classified as the most effective and expensive vapor barriers. This group of products contains both single-sided and double-sided materials

The former allow steam to pass through only in one direction, so during installation it is extremely important not to confuse which side to lay the fabric towards the insulation and which to the load-bearing surface. Double-sided ones work in both directions, so there are no problems with them

Vapor barrier membranes can be single-layer or multi-layer. The first ones have an affordable price. Multilayer ones have the function of accumulating moisture inside the canvas and gradually releasing it.

A special group of products in this category are “smart” membranes. They are able not only to absorb vapors, but also to regulate the level of humidity of surrounding materials, while simultaneously acting as a water barrier. These membranes are the best choice. But their cost is beyond the means of most private home owners.

Vapor barrier membranes "TechnoNIKOL"

The undoubted leader in this category of materials is TechnoNikol membranes. For vapor barrier of wooden ceilings, the “Optima” brand is recommended for use. This hydrophobic polypropylene membrane consists of three layers:

  • upper and lower polypropylene;
  • medium – high-tech functional vapor-permeable film.
  • weight 80 g/m2;
  • thickness 0.3 mm;
  • vapor permeability 5 g/m2x24 hours.

The TechnoNIKOL Optima membrane is produced in rolls. The width of the canvas (roll height) is 1.5 m. The length is 50 m. This material is optimal for vapor barrier of any type of ceiling, intended for installation indoors and on external surfaces of buildings.

Superdiffuse reinforced membrane

Diffusion membrane films "TechnoNikol"

Rules for installing a vapor barrier for a wooden ceiling

Step 1. The membrane is laid directly on the insulation so that the smooth side is directed inside the room.

Step 2. It is possible to lay the strips in different directions: parallel or perpendicular to each other.

Step 3. During installation, an overlap of at least 10 cm must be observed.

Step 4. To attach the membrane to a wooden floor without insulation, use galvanized screws with wide heads or staples with an anti-corrosion coating.

Step 5. The joints of the canvases are sealed using self-adhesive mounting tape.

Use foil tape, width 50 mm, length 30 lm.

Step 6. When laying on a floor with insulation, it is necessary to bring the edges of the panels onto the wall by 15-20 cm and secure them with suitable materials (slats or metal profiles).

Step 7. Mounting tape is glued along the perimeter of the vapor barrier layer.

Step 8. Between the membrane and the material with which the wooden floor will be lined, leave a ventilation gap 3-4 cm wide.

Step 9. Particular attention is required to the places where the vapor barrier comes into contact with the structural elements of the floor and the building: beams, chimneys, ventilation ducts.

Ceiling vapor barrier in wooden floors

During installation of the vapor barrier, it is necessary to ensure that the film is laid evenly, without folds or sagging. A guideline for correct installation can be a colored stripe, which is the center line along the entire length of the canvas.

Video - Ceiling vapor barrier

An equally good choice are multilayer vapor barrier membranes of other brands: Dorken Delta REFLEX/REFLEX PLUS and Dorken Delta LUXX. The first is a four-layer material, is particularly durable and can provide 100% waterproofing of a wooden floor. The second has limited vapor permeability, ensuring gradual and uniform removal of moisture from the living space.

Insulation of the attic floor

Insulation of the attic floor, taking into account wooden beams, is an important stage, both from the point of view of the choice of material and from the point of view of installation. The correct choice of material for thermal insulation should take into account the following factors:

  • price;
  • availability;
  • ease of installation;
  • climatic conditions;
  • environmental friendliness;
  • fire safety.

Do not forget about the weight of the insulation, so as not to create unnecessary stress on the entire structure of the building.

There are many offers on the modern building materials market. Here are some types of insulation that are most in demand:

  1. Expanded clay, bulk material, light weight, with high heat-saving characteristics, low cost;
  2. Vermiculite, a natural bulk insulation with similar properties;
  3. Perlite, a bulk insulation material of natural origin, which has approximately the same thermal conductivity;
  4. Mineral wool, available in rolls and slabs, insulation with low thermal conductivity and high environmental performance. Read more in the article technology of attic insulation with mineral wool;
  5. Glass wool, an analogue of mineral wool, which is of artificial origin, has greater chemical resistance compared to mineral wool;
  6. Expanded polystyrene, produced in the form of slabs, is afraid of rodents, has rather low thermal insulation properties and low cost;
  7. Extruded polystyrene foam, non-flammable, has a higher heat-saving ability than regular polystyrene foam;
  8. Polyurethane foam, produced in slabs, has excellent heat resistance; when sprayed, it creates a continuous protective film for heat and waterproofing.
  9. Peat slabs made from moss, which are of natural origin, are moisture resistant, light in weight and have excellent thermal protection;
  10. Reed, the most practical and cheapest material, with excellent characteristics, which you can make with your own hands.

If the thickness of the insulation is higher than the beams, you need to make additional laying of the slats to create an air gap. Bulk insulation is distributed evenly between the beams, the slabs are laid end-to-end, without gaps.

Attic waterproofing

After the interfloor pie is ready and the floor is installed, you should think about waterproofing the cold attic space. Some advise abandoning it altogether, but still, it won’t hurt to lay a layer of waterproofing material under the roof. To avoid leaks of condensate, diffusion membranes should be installed. There will be no snow or rain, which significantly reduce the thermal insulation properties of the attic. Waterproofing is especially necessary if corrugated sheeting is used as a roofing material.

The attic floor separates the heated part of the building from the cold part. Choosing the right material and insulator thickness means reducing heat loss and saving material costs during the heating season. Let's talk about insulating the attic floor using wooden beams with your own hands.

Roof tiles

There are several types of roofing material where this term is present:

  1. Bituminous shingles. Waterproofing is provided at the level of installation technology from the manufacturer. This is a lining carpet that also serves as an additional fixing element. The bitumen contained in shingles and carpet bakes together when the roof heats up from the sun.
  2. Composite tiles. This is a kind of metal tile with a small sheet size. The differences lie in the composition of the protective and decorative layer. As with any metal roof, waterproofing must be installed underneath it.
  3. Ceramic and cement-sand tiles. They differ from each other in composition, shape, manufacturing technology. But despite this, installation proceeds according to general principles. And the manufacturers of these types of roofing, when describing the installation technology, also stipulate the presence of waterproofing.

Construction of a wooden attic floor

The load-bearing elements in the attic wooden floor are beams. They are made from coniferous wood. The cross-sectional size of the beams is taken based on the load that the element absorbs. We told you about the correct calculation of wooden floor beams in the article “How to calculate wooden floor beams.”

For each specific climatic conditions and depending on the ability of the material to resist heat transfer, according to the thermal engineering calculation, its own value for the thickness of the heat insulator is obtained.


Scheme of attic floor insulation: 1 - joists; 2 — cranial bars; 3 - plank board or boards; 4 - vapor barrier; 5 - counter-lattice for ventilation gap; 6 - insulation; 7 - clean floor; 8 - ventilation gap

A subfloor made of wooden panels or boards is mounted on skull blocks. Next, a membrane-type vapor barrier is laid, insulation is laid on it, which is covered with another layer of membrane.

If the attic is in use, a clean floor is laid on top. If not, then running boards (min. 40 mm thick) are laid along the beams. All wooden elements are antiseptic. To ventilate wooden structures, when laying a clean floor, a gap is left between it and the insulation.

Calculation of the number of elements and their sizes

The calculation of floor beams, their cross-section and the step between them must be known in order for the attic floor to be as stable as possible for the loads placed on it. To do this, the developer must understand for what purpose the attic will be used. The classification is as follows :

  • unused premises;
  • storage space;
  • living space.

There are standards for each listed type. So, the initial value is the weight of the ceiling itself, which consists of wood and light insulation; it is equal to 50 kgf/m² (kilogram-force per meter²).


  1. For non-residential premises on which there will be no furniture, unnecessary things, etc., the specific gravity, according to the SNiP table, is 100 kgf/m².

  2. The room where equipment, old furniture, boxes, boxes and the weight of the person himself are stored has a mass of 200 kgf/m².
  3. A living space equipped as an attic floor, with insulation, furniture and constant human visits, has a weight of 300 kgf/m².

Thus, we add the weight of the living space to the initial value of 50 kgf/m² and, checking the SNiP table, which takes into account the dimensions and pitch of the beams for each weight, we calculate the required lumber.

Selection of material for insulation

Bulk materials

Expanded clay

You can insulate attic floors using bulk materials, which include expanded clay. It has a relatively low weight (250–600 kg/m3) and high resistance to heat transfer. Ease of installation and relative low cost determine the choice of this material.

Vermiculite

Expanded vermiculite is obtained by heating vermiculite rock to a temperature of 700 ° C, which at the same time increases in volume by 25 times. Its thermal conductivity ranges from 0.13 W/m·K, and its volumetric weight is up to 200 kg/m3.

Perlite

Expanded perlite also belongs to bulk thermal insulation materials. Perlite rock is crushed and fired to produce a porous structure. Expanded perlite is environmentally friendly, does not burn and is bioresistant, and has high thermal insulation properties (0.052 W/m K). Its volumetric weight is 160–250 kg/m3.

Rating
( 2 ratings, average 4.5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]